IEC60092 Offshore & Marine Cable

IEC 60092


  • MariTox Marine Flame Retardant Medium Voltage Cables
  • MariTox Marine Flame Retardant Power & Control Cables
  • MariFlex Marine Fire Resistant Power & Control Cables
  • MariSig Flame Retardant Instrumentation & Control Cables
  • MariSig Fire Resistant Instrumentation & Control Cables
  • MariLan Marine Lan Data & Communication Cables

IEC 60092

Armoured Cat 5e SF/UTP 24AWG

Application

These Cat5e SF/UTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all Class D applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for basic voice and data installations up to 100MHz.

Standards

  • EN 50288
  • ISO 11801
  • IEC 61156-5
  • IEC 60332-1
  • IEC 60754-1/2
  • IEC 61034

Construction

Armoured Cat 5e SF/UTP 24AWG
  • Conductors: Bare copper conductor.
  • Insulation: PE.
  • Twinning: Two coloured insulated conductors twisted together to form a pair.
  • Overall Screen1: Al/polyester tape.
  • Overall Screen2: Tinned copper wire braid.
  • Inner Sheath: LSOH.
  • Armour: Tinned copper wire braid.
  • Outer Sheath: LSOH (SHF1).

Core Identification

  • Pair 1: White/Blue, Blue
  • Pair 2: White/Orange, Orange
  • Pair 3: White/Green, Green
  • Pair 4: White/Brown, Brown

Electrical Properties

Maximum Loop Resistance Ω/km 190
Maximum Resistance Unbalance   2%
Minimum Insulation Resistance MΩ.km 1000
Nominal Capacitance @800Hz nF/km 48
Maximum Capacitance Unbalance (pair to ground) pF/km 1500
Characteristic Impedance @1-100MHz Ω 100 ± 15
Nominal Velocity of Propagation   ca. 67%
Maximum Propagation Delay ns/100 m 535
Maximum Delay Skew ns/100 m 20
Maximum Transfer Impedance @1MHz mΩ /m 20
Maximum Transfer Impedance @10MHz mΩ /m 20
Maximum Transfer Impedance @30MHz mΩ /m 30
Maximum Transfer Impedance @100MHz mΩ /m 60
Minimum Coupling Attenuation dB 75

Nominal Transmission Characteristics @20℃

F Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return Loss
MHz dB/100m dB dB dB/100m dB/100m dB/100m dB/100m dB
1 1.9 71 68 69.1 66.1 68 65 20
4 3.7 62 59 58.3 55.3 56 53 23
10 6.0 56 53 50 47.0 48 45 25
16 7.6 53 50 45.4 42.4 44 41 25
20 8.5 51 48 42.5 39.5 42 39 25
31.2 10.7 49 46 38.3 35.3 38 35 24
62.5 15.7 44 41 28.2 25.3 32 29 22
100 19.8 41 38 21.2 18.2 28 25 20
125.0 22.3 40 37 17.7 14.7 26 23 19
155.5 24.2 38 35 13.8 10.8 24 21  
175.0 25.7 37 34 11.3 8.3 23 20  
200.0 27.5 36 33 8.5 5.5 22 19  
250.0 29.2 35 32 5.8 2.8 20 17  
300.0 32.0 34 31 2.0 1.0 16 13  

Mechanical and Thermal Properties

  • Bending Radius: 8×OD (during installation); 4×OD (fixed installed)
  • Temperature Range: -20℃ ~ +60℃

Dimensions and Weight

Part No. Construction
  • No. of elements×No. of cores in element×Cross section(mm²)
  • Nominal Insulation Thickness
  • mm
  • Nominal Sheath
  • Thickness mm
  • Nominal Overall Diameter
  • mm
  • Nominal Weight kg/km
    Inner Outer
    MLN-SF/UTPCAT5EA4P24 4×2×24AWG 0.25 0.74 1.22 10.5 173

     