• Home
  • About Caledonian
  • Products IEC 60092 Offshore Cables | BS 6883 Offshore Cables | JIS shipboard cables | NEK606 Offshore Cables | Water Blocked NEK606 offshore cables
  • Applications Reference List | Industry
  • Technical Information Material Properties | Standards | Fire Testing | Customized Products | Product Certificates | Cable Glossary | FAQ
  • Download
  • Link Testing Authorities | Testing Equipment Manufacturers | Magazines | Articles | Exhibition News | Organizations | Caledonian Corporater Website
  • Exhibition News
  • Sitemap
  • Contacts
  • Chinese

IEC60092 Offshore & Marine Cable

IEC 60092


  • MariTox Marine Flame Retardant Medium Voltage Cables
  • MariTox Marine Flame Retardant Power & Control Cables
  • MariFlex Marine Fire Resistant Power & Control Cables
  • MariSig Flame Retardant Instrumentation & Control Cables
  • MariSig Fire Resistant Instrumentation & Control Cables
  • MariLan Marine Lan Data & Communication Cables

IEC 60092

Cat 5e F/UTP 24AWG

Application

These Cat5e F/UTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all Class D applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for basic voice and data installations up to 100MH

Standards

  • EN 50288
  • ISO 11801
  • IEC 61156-5
  • IEC 60332-1
  • IEC 60754-1/2
  • IEC 61034

Construction

Cat 5e F/UTP 24AWG
  • Conductors: Solid bare copper conductor.
  • Insulation: PE.
  • Twinning: Two coloured insulated conductors twisted together to form a pair.
  • Overall Screen: Al/polyester tape.
  • Drain Wire: Tinned copper wire.
  • Outer Sheath: LSOH.

Core Identification

  • Pair 1: White/Blue, Blue
  • Pair 2: White/Orange, Orange
  • Pair 3: White/Green, Green
  • Pair 4: White/Brown, Brown

Electrical Properties

Maximum Loop Resistance Ω/km 190
Maximum Resistance Unbalance   2%
Minimum Insulation Resistance MΩ.km 1000
Nominal Capacitance @800Hz nF/km 48
Maximum Capacitance Unbalance (pair to ground) pF/km 1500
Characteristic Impedance @1-100MHz Ω 100 ± 15
Nominal Velocity of Propagation   ca. 67%
Maximum Propagation Delay ns/100 m 535
Maximum Delay Skew ns/100 m 20
Maximum Transfer Impedance @1MHz mΩ /m 50
Maximum Transfer Impedance @10MHz mΩ /m 100
Maximum Transfer Impedance @30MHz mΩ /m 200
Minimum Coupling Attenuation dB 55

Nominal Transmission Characteristics @20℃

F Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return Loss
MHz dB/100m dB dB dB/100m dB/100m dB/100m dB/100m dB
1 1.9 71 68 69.1 66.1 68 65 20
4 3.7 62 59 58.3 55.3 56 53 23
10 6.0 56 53 50 47.0 48 45 25
16 7.6 53 50 45.4 42.4 44 41 25
20 8.5 51 48 42.5 39.5 42 39 25
31.2 10.7 49 46 38.3 35.3 38 35 24
62.5 15.7 44 41 28.2 25.3 32 29 22
100 19.8 41 38 21.2 18.2 28 25 20
125.0 22.3 40 37 17.7 14.7 26 23 19
155.5 24.2 38 35 13.8 10.8 24 21  
175.0 25.7 37 34 11.3 8.3 23 20  
200.0 27.5 36 33 8.5 5.5 22 19  
250.0 29.2 35 32 5.8 2.8 20 17  
300.0 32.0 34 31 2.0 1.0 16 13  

Mechanical and Thermal Properties

  • Bending Radius: 8×OD (during installation); 4×OD (fixed installed)
  • Temperature Range: -20℃ ~ +60℃

Dimensions and Weight

Part No. Construction
  • No. of elements×No. of cores in element×Cross section(mm²)
  • Nominal
  • Insulation Thickness mm
  • Nominal Sheath Thickness mm Nominal Overall
  • Diameter mm
  • Nominal Weight kg/km
    MLN-F/UTPCAT5E4P24 4×2×24AWG 0.25 0.75 6.97 54

     

    CALEDONIAN

    27 Old Gloucester Street,

    London, WC1N 3AX

    Tel: 44-207-4195087

    Fax: 44-207-8319489

    Email:enquiry@shipboard-cables.com

    Caledonian Cables|FAQ|© 2013