• Home
  • About Caledonian
  • Products IEC 60092 Offshore Cables | BS 6883 Offshore Cables | JIS shipboard cables | NEK606 Offshore Cables | Water Blocked NEK606 offshore cables
  • Applications Reference List | Industry
  • Technical Information Material Properties | Standards | Fire Testing | Customized Products | Product Certificates | Cable Glossary | FAQ
  • Download
  • Link Testing Authorities | Testing Equipment Manufacturers | Magazines | Articles | Exhibition News | Organizations | Caledonian Corporater Website
  • Exhibition News
  • Sitemap
  • Contacts
  • Chinese

IEC60092 Offshore & Marine Cable

IEC 60092


  • MariTox Marine Flame Retardant Medium Voltage Cables
  • MariTox Marine Flame Retardant Power & Control Cables
  • MariFlex Marine Fire Resistant Power & Control Cables
  • MariSig Flame Retardant Instrumentation & Control Cables
  • MariSig Fire Resistant Instrumentation & Control Cables
  • MariLan Marine Lan Data & Communication Cables

IEC 60092

Cat 6 U/FTP 23AWG

Application

These Cat6 U/FTP cables are manufactured in accordance with IEC 61156-5 requirements, can support all Class E applications like Ethernet, Fast Ethernet, Gigabit Ethernet, suitable for basic voice and data installations up to 250MHz.

Standards

  • EN 50288
  • ISO 11801
  • IEC 61156-5
  • IEC 60332-1
  • IEC 60754-1/2
  • IEC 61034

Construction

Cat 6 U/FTP 23AWG
  • Conductors: Solid bare copper conductor.
  • Insulation: PE.
  • Twinning: Two coloured insulated conductors twisted together to form a pair.
  • Individual Screen: Al/polyester tape.
  • Outer Sheath: LSOH.

Core Identification

  • Pair 1: White, Blue
  • Pair 2: White, Orange
  • Pair 3: White, Green
  • Pair 4: White, Brown

Electrical Properties

Maximum Loop Resistance Ω/km 145
Maximum Resistance Unbalance   2%
Minimum Insulation Resistance MΩ.km 1000
Nominal Capacitance @800Hz nF/km 45
Maximum Capacitance Unbalance (pair to ground) pF/km 800
Characteristic Impedance @1-100MHz Ω 100 ± 5
Nominal Velocity of Propagation   0.75c
Maximum Propagation Delay ns/100 m 500
Maximum Delay Skew ns/100 m 20
Maximum Transfer Impedance @1MHz mΩ /m 50
Maximum Transfer Impedance @10MHz mΩ /m 100
Maximum Transfer Impedance @30MHz mΩ /m 200
Minimum Coupling Attenuation dB 55

Nominal Transmission Characteristics @20℃

F Attenuation NEXT PS-NEXT ACR PS-ACR ELFEXT PS-ELFEXT Return Loss
MHz dB/100m dB dB dB/100m dB/100m dB/100m dB/100m dB
1 2.0 90 87 88 85 85 82  
4 3.6 90 87 86 83 85 82 27
10 5.7 90 87 84 81 79 76 30
16 7.2 90 87 83 80 75 72 30
20 8.1 90 87 82 79 73 70 30
31.25 10.2 90 87 80 77 69 66 30
62.50 14.7 90 87 75 72 63 60 30
100 18.9 90 87 71 68 59 56 30
155 24.0 88 85 64 61 55 52 26
200 27.0 88 85 61 58 53 50 25
250 31.4 86 83 55 52 51 48 25
300 34.8 86 83 51 48 49 46 23
400 38.1 86 83 48 45 44 41 23

Mechanical and Thermal Properties

  • Bending Radius: 8×OD (during installation); 4×OD (fixed installed)
  • Temperature Range: -20℃ ~ +60℃

Dimensions and Weight

Part No. Construction
  • No. of elements×No. of cores in element×Cross section(mm²)
  • Nominal Insulation Thickness mm Nominal Sheath Thickness mm Nominal Overall
  • Diameter mm
  • Nominal Weight kg/km
    MLN-U/FTPCAT64P23 4×2×23AWG 0.23 0.63 7.5 61

     

    CALEDONIAN

    27 Old Gloucester Street,

    London, WC1N 3AX

    Tel: 44-207-4195087

    Fax: 44-207-8319489

    Email:enquiry@shipboard-cables.com

    Caledonian Cables|FAQ|© 2013