• Home
  • About Caledonian
  • Products IEC 60092 Offshore Cables | BS 6883 Offshore Cables | JIS shipboard cables | NEK606 Offshore Cables | Water Blocked NEK606 offshore cables
  • Applications Reference List | Industry
  • Technical Information Material Properties | Standards | Fire Testing | Customized Products | Product Certificates | Cable Glossary | FAQ
  • Download
  • Link Testing Authorities | Testing Equipment Manufacturers | Magazines | Articles | Exhibition News | Organizations | Caledonian Corporater Website
  • Exhibition News
  • Sitemap
  • Contacts
  • Chinese

IEC60092 Offshore & Marine Cable

IEC 60092


  • MariTox Marine Flame Retardant Medium Voltage Cables
  • MariTox Marine Flame Retardant Power & Control Cables
  • MariFlex Marine Fire Resistant Power & Control Cables
  • MariSig Flame Retardant Instrumentation & Control Cables
  • MariSig Fire Resistant Instrumentation & Control Cables
  • MariLan Marine Lan Data & Communication Cables

IEC 60092

MFX300 0.6/1 kV Fire Barriers + HEPR Insulated, LSOH (SHF1)Sheathed, Screened Fire Resistant Power & Control Cables(Single Core)pdf

Application

These cables are used for fixed installations on ships and offshore units in all locations and on open deck in safety circuits, where fire resistance is required. The good screening qualities of the copper braid also reduce radio interference and electrical influences to electronics installations. These cables are fire resistant, flame retardant, low smoke & halogen free.

Standards

  • DIN 89160/98
  • IEC 60092-353
  • IEC 60331-21
  • IEC 60332-1
  • IEC 60332-3-22
  • IEC 60754-1/2
  • IEC 61034

Construction

IEC60092 Offshore & Marine Cable
  • Conductors: Class 2 stranded copper conductor.
  • Insulation: Fire barriers + HEPR.
  • Overall Screen: Copper wire braid.
  • Outer Sheath: LSOH (SHF1).

Core Identification

Single core: Natural colour (beige).

Mechanical and Thermal Properties

  • Bending Radius for Fixed Installations: 6×OD
  • Temperature Range: -20℃ ~ +75℃

Dimensions and Weight

Part No. Construction No. of cores×Cross section(mm²) Nominal Insulation Thickness mm Nominal Sheath Thickness mm Nominal Overall Diameter mm Nominal Weight kg/km
MFX300-1mG7MZ1-R-1C25 1×25 0.9 1.2 12.5 380
MFX300-1mG7MZ1-R-1C35 1×35 0.9 1.2 13.5 480
MFX300-1mG7MZ1-R-1C50 1×50 1.0 1.3 15.5 670
MFX300-1mG7MZ1-R-1C70 1×70 1.1 1.4 17.5 900
MFX300-1mG7MZ1-R-1C95 1×95 1.1 1.4 19.5 1170
MFX300-1mG7MZ1-R-1C120 1×120 1.6 1.5 21.0 1430
 

CALEDONIAN

27 Old Gloucester Street,

London, WC1N 3AX

Tel: 44-207-4195087

Fax: 44-207-8319489

Email:enquiry@shipboard-cables.com

Caledonian Cables|FAQ|© 2013