250V
[FA-] MPYS, MPYCS, MPYCYS
Standards
JISC 3410-1999
IEC 60332-1
IEC 60332-3 Cat.A(for FA-type)
Cable Construction
Conductor |
M |
Tinned annealed stranded copper, class 2 according to IEC 60228 |
Insulation |
P |
85°C EPR as per JIS C 3401 |
Cabling |
|
Insulated conductors shall be cabled. |
Overall shield |
S |
Tinned copper wire braid |
Bedding |
Y |
PVC as per JIS C 3401 |
Armor |
C |
Galvanized steel wire braid |
Sheath |
Y |
PVC as per JIS C 3401 |
Core identification |
|
Black No. on white insulation |
Outer sheath color |
|
Black |
Cable Parameter
250V (FA-) MPYS
No. of cores |
Conductor | Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
(FA-) MPYS | ||||
Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.1 |
9.4 |
0.4 |
135 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.1 |
10.6 |
0.5 |
190 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.2 |
12.6 |
0.6 |
270 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
0.16 |
1.3 |
16.3 |
0.7 |
430 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
0.16 |
1.5 |
19.3 |
0.8 |
600 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.6 |
23 |
1 |
840 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.7 |
25.7 |
1.1 |
1070 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.8 |
28.9 |
1.2 |
1290 |
250V (FA-) MPYCS
No. of cores |
Conductor | Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
Dia. of steel wire |
(FA-) MPYCS | ||||
Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
|||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.1 |
0.3 |
10.7 |
0.4 |
205 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.1 |
0.3 |
11.9 |
0.5 |
260 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.2 |
0.3 |
13.9 |
0.6 |
355 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
0.16 |
1.3 |
0.3 |
17.6 |
0.7 |
540 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
0.16 |
1.5 |
0.3 |
20.6 |
0.8 |
735 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.6 |
0.3 |
24.3 |
1 |
995 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.7 |
0.3 |
27 |
1.1 |
1240 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.8 |
0.3 |
30.2 |
1.2 |
1480 |
250V (FA-) MPYCYS
No. of cores |
Conductor | Thick. of insulation |
Dia. of shield wire |
Thick. of bedding |
Dia. of steel wire |
Thick. of covering |
(FA-) MPYCYS | ||||
Size | Construction | O.D | Nom. overall dia |
Tolerance | Cable Weight |
||||||
mm² | No./mm | mm | mm | mm | mm | mm | mm | mm | mm | kg/km | |
2 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.1 |
0.3 |
0.9 |
12.7 |
0.5 |
255 |
4 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.1 |
0.3 |
0.9 |
13.9 |
0.6 |
315 |
7 |
1 |
7/0.43 |
1.29 |
0.7 |
0.14 |
1.2 |
0.3 |
0.9 |
15.9 |
0.6 |
420 |
12 |
1 |
7/0.43 |
1.29 |
0.7 |
0.16 |
1.3 |
0.3 |
1 |
19.8 |
0.8 |
625 |
19 |
1 |
7/0.43 |
1.29 |
0.7 |
0.16 |
1.5 |
0.3 |
1.1 |
23 |
0.9 |
850 |
27 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.6 |
0.3 |
1.2 |
26.9 |
1.1 |
1140 |
37 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.7 |
0.3 |
1.3 |
29.8 |
1.2 |
1410 |
44 |
1 |
7/0.43 |
1.29 |
0.7 |
0.18 |
1.8 |
0.3 |
1.4 |
33.2 |
1.3 |
1680 |