P19 or P19/P21 RFOU 12/20KV
    Applications
These cables are flame retardant, low smoke, halogen free and mud resistant, used for fixed installation for medium voltage power.
Standards
| IEC 60092-353 | IEC 60092-351 | 
| IEC 60092-359 | IEC 60332-1 | 
| IEC 60332-3-22 | IEC 60754-1,2 | 
| IEC 61034-1,2 | NEK 606:2004 | 
![]()  | 
         ![]()  | 
       
Construction
- Conductors : Circular tinned annealed stranded copper to IEC 60228 class 2.
 - Conductor Screen : Semi conducting material.
 - Insulation : Halogen-free EPR. XLPE can be offered as an option (for TFOU cable).
 - Insulation Screen : Semi conducting material and tinned copper wire braid.
 - Bedding : Halogen free compound.
 - Armour : Tinned copper wire braid.
 - Outer Sheath : Halogen free thermosetting compound, SHF2 (for TYPE P19), or halogen free mud resistant thermosetting compound, SHF MUD (for TYPE P19/P21),coloured red.
 
Optional
- P20 or P20/P22 RFOU/TFOU 18/30(36) kV.
 
Electrical Characteristics
| Nominal Cross Section Area | mm² | 16 | 25 | 35 | 50 | 70 | 95 | 
| Nominal Conductor Diameter | mm | 5.2 | 6.5 | 7.4 | 8.7 | 10.3 | 12.2 | 
| Maximum DC Resistant@20℃ | Ω/km | 1.16 | 0.734 | 0.529 | 0.391 | 0.27 | 0.195 | 
| Continuous Current Rating@45℃1 Core | A | 96 | 127 | 157 | 196 | 242 | 293 | 
| Continuous Current Rating@45℃3 Core | A | 67 | 89 | 110 | 137 | 169 | 205 | 
| Short Circuit Current 1s | A | 2290 | 3580 | 5010 | 7150 | 10020 | 13590 | 
| Operating Voltage | KV | 12/20 | 12/20 | 12/20 | 12/20 | 12/20 | 12/20 | 
| Nominal Cross Section Area | mm² | 120 | 150 | 185 | 240 | 300 | 
| Nominal Conductor Diameter | mm | 13.8 | 15.1 | 17.0 | 19.6 | 21.9 | 
| Maximum DC Resistant@20℃ | Ω/km | 0.154 | 0.126 | 0.1 | 0.0762 | 0.0607 | 
| Continuous Current Rating@45℃1 Core | A | 339 | 389 | 444 | 522 | 601 | 
| Continuous Current Rating@45℃3 Core | A | 237 | 272 | 311 | 365 | 421 | 
| Short Circuit Current 1s | A | 17170 | 21460 | 26470 | 34340 | 42930 | 
| Operating Voltage | KV | 12/20 | 12/20 | 12/20 | 12/20 | 12/20 | 
Ambient Temperature Correction Factors
| Ambient Temperature Correction Factors | 35 | 40 | 45 | 50 | 55 | 60 | 65 | 70 | 75 | 80 | 
| Rating Factor | 1.1 | 1.05 | 1.0 | 0.94 | 0.88 | 0.82 | 0.74 | 0.67 | 0.58 | 0.47 | 
Mechanical and Thermal Properties
- Bending Radius :15×OD (during installation); 9×OD (fixed installed).
 - Temperature Range : -20℃ ~ +90℃.
 
Dimensions and Weight
| Construction No. of cores×Cross   section (mm²)  | 
         Nominal Insulation Thickness mm  | 
         Nominal Sheath Thickness mm  | 
         Nominal Overall Diameter mm  | 
         Nominal Weight kg/km  | 
       |
|---|---|---|---|---|---|
| Inner | Outer | ||||
| 1×16 | 5.5 | 1.4 | 1.2 | 28 | 1200 | 
| 1×25 | 5.5 | 1.5 | 1.2 | 31.6 | 1530 | 
| 1×35 | 5.5 | 1.8 | 1.3 | 32.3 | 1595 | 
| 1×50 | 5.5 | 1.8 | 1.4 | 33.8 | 1795 | 
| 1×70 | 5.5 | 1.9 | 1.4 | 34.6 | 2070 | 
| 1×95 | 5.5 | 2.0 | 1.5 | 37.0 | 2470 | 
| 1×120 | 5.5 | 2.0 | 1.5 | 38.8 | 2810 | 
| 1×150 | 5.5 | 2.1 | 1.6 | 40.7 | 3245 | 
| 1×185 | 5.5 | 2.2 | 1.6 | 42.9 | 3765 | 
| 1×240 | 5.5 | 2.3 | 1.7 | 45.8 | 4510 | 
| 1×300 | 5.5 | 2.4 | 1.8 | 48.5 | 5315 | 
| 3×16 | 5.5 | 1.8 | 2.0 | 55.5 | 4950 | 
| 3×25 | 5.5 | 1.9 | 2.0 | 62.2 | 5705 | 
| 3×35 | 5.5 | 2.9 | 2.1 | 62.6 | 5990 | 
| 3×50 | 5.5 | 3.0 | 2.2 | 65.4 | 6740 | 
| 3×70 | 5.5 | 3.1 | 2.3 | 69.1 | 7790 | 
| 3×95 | 5.5 | 3.3 | 2.4 | 73.0 | 9150 | 
| 3×120 | 5.5 | 3.4 | 2.5 | 77.4 | 10580 | 
| 3×150 | 5.5 | 3.6 | 2.6 | 81.9 | 12145 | 
| 3×185 | 5.5 | 3.8 | 2.7 | 89.5 | 12265 | 
| 3×240 | 5.5 | 4.0 | 2.9 | 96.1 | 14725 | 
| 3×300 | 5.5 | 4.2 | 3.0 | 101.9 | 17190 | 