RG213 Armoured Coaxial Cable
Applications
These 50Ω coaxial cables are suitable for installation on board of ships and other indoor marine environments.
Standards
IEC 60092-350 |
IEC 60332-3-22 |
IEC 60754-1,2 |
IEC 61034-1,2 |
NEK 606:2004 |
|
Construction
- Conductors : 13AWG tinned copper.
- Insulation : PE.
- Shielding : Tinned copper braid.
- Bedding : Low smoke and halogen-free polyolefin, coloured black.
- Armour : Tinned Copper wire braid.
- Outer Sheath : Low smoke and halogen-free polyolefin.
Electrical Characteristics
AWG |
|
13 |
Conductor Construction No./Diameter of Wires |
-/mm |
7/0.75 |
Nominal Conductor Diameter |
mm |
2.24 |
Impedance |
Ω |
50+/-3 |
Nominal Attenuation@100MHz |
dB/100m |
7.5 |
Nominal Attenuation@200MHz |
dB/100m |
10.5 |
Nominal Attenuation@400MHz |
dB/100m |
15.1 |
Nominal Attenuation@1000MHz |
dB/100m |
29.5 |
Capacitance |
pF/m |
101 |
Velocity of Propagation |
% |
66 |
Conductor DCR |
Ω/km |
5.7 |
Shield DCR |
Ω/km |
3.9 |
Inductance |
μH/m |
0.246 |
Time Delay |
ns/m |
5.0 |
Mechanical and Thermal Properties
- Bending Radius : 15×OD.
- Temperature Range : -30℃ ~ +75℃.
Dimensions and Weight
Nominal Inner Conductor Diameter mm |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
2.24 |
2.2 |
1.14 |
13.9 |
379 |