P16 IFLI 250 V
Applications
- These cables are flame retardant, low smoke and halogen free, used for living, quarter and office areas.
Standards
-
IEC 60092-376 IEC 60092-351 IEC 60092-359 IEC 60332-1 IEC 60332-3-22 IEC 60754-1,2 IEC 61034-1,2 NEK 606:2004
Construction
- Conductors : Circular stranded copper wire to IEC 60228 class 2.
- Insulation : XLPE.
- Bedding : Halogen free thermoplastic compound.
- Metal Screen : Longitudinal aluminium tape, thickness 0.2 mm in contact with a stranded copper earth conductor.
- Outer Sheath : Halogen free thermoplastic compound, SHF1, coloured grey.
Electrical Characteristics
-
Nominal Cross Section Area mm² 2.5 Maximum Resistant@20℃ Ω/km 7.41 Continuous Current Rating@45℃2 Core A 26 Short Circuit Current 1s A 360 Operating Voltage V 250
Mechanical and Thermal Properties
- Bending Radius : 8×OD (during installation); 6×OD (fixed installed).
- Temperature Range : -20℃ ~ +90℃.
Dimensions and Weight
Construction No. of elements×No. of cores in element×Cross section (mm²) |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|
Inner | Outer | ||||
2×1×2.5 | 0.7 | 1.1 | 1.2 | 10.0 | 180 |