NEK606 Offshore & Marine Cable
Cable Characteristics
Mud Resistant
The suitability of sheathing materials for use in areas in which the cables are exposed to
drilling fluids is heavily dependent upon the type of fluid present. Each type of fluid contains
additives which can have a deleterious effect on the sheathing material.
According to NEK 606, the mud resistant cables shall have a SHF Mud sheath that comply
with the requirements in IEC 60092-359 for SHF2 and the below specified. The mud resistant
cables shall be designed with sheathing compounds suitable for installation and operation in
contact with MUD unless otherwise specified.
Oil Resistance
All thermoset sheathed cables shall be suitable for an oil production installation. The oil
resistance properties shall be demonstrated by a test according to IEC 60092-359 SHF2.
Flame Retardance
The cables shall withstand the test specified in IEC 60332-3-10, -22, -23, -24, -25. Single,
earth and bonding wires shall withstand the test specified in IEC 60332-1 or IEC 60332-2.
Fire Resistance
Fire resistance cables shall be tested according to IEC 60331-11, -12, -21, -25 and -31.